CII-SR-476

Validation message

Only one AdditionalReferencedDocument AttachmentBinaryObject BT-125 is allowed with TypeCode 916.

Explanation

An additional supporting document (BG-24) may contain only one attached file (BT-125). The current European version of this rule is defective, so XRechnung downgrades it to information and checks the same thing correctly with BR-TMP-5.

How to fix

No action needed unless BR-TMP-5 is also reported.

Applies to

  • EN 16931 (CII)